Reset
|
: |
Automatic or Manual - Selectable |
| Display |
: |
4 digit, 2" Height Red LED Display |
| Range |
: |
1000 - 1800o C (500-1400o C for K type) |
| Input |
: |
R, S, B or K Thermocouple - Selectable |
| Measuring Principle |
: |
Plateau, Averaging or Peak - Selectable |
| Clock |
: |
Time, internal, clock-battery backed. |
| Compensation |
: |
Cold junction compensation automatic. |
| Data Memory |
: |
Last 190 readings - battery backed-Printable with date and time. |
| Outputs |
: |
a) Temperature Result on 2" Ht 4 digit LED
Display
b) Bright, Green, Amber and Red lamps for status
indication with Hooter
c) 4 digit result in current loop at 220 Hz bit rate
until reset.
d) parallel port for Printer
e) RS-232 for PC communication
f) 4-20 mA output until reset. |
| Dimensions |
: |
19" Rack Mounting (483 x 140 x 265mm)
Cut out : 403 x 133 |
| Optional Accessories |
: |
Wall or Floor-mounting MS Panel Remote Large Display Unit ARD-02 Remote Status Indicator Lamps 80 column Dot Matrix Printer Digital Calibration Unit Model ALC-02 12 ft Lance, Compensating Cable Thermocouple Tips, Receptacles & Housing |
| Configuration & Dimensions subject to change |